Ultrasonic flowmeters are suitable for flow measurement in pipes of various sizes. The flow velocity measurement range is 0.01 to +32m/s. The measured medium is a single stable liquid such as water, seawater, sewage, and alcohol. The measured material is uniform and dense pipes such as steel, stainless steel, cast iron, PVC, and fiberglass reinforced plastic.
Technical indicators
1.Measurement accuracy :1%
2. Working power supply: Isolated DC8-36V or AC85-264V;
3. Power consumption: Operating current 50mA(under the condition that the keyboard is not connected and the buzzer does not sound);
4. Optional output :1. Road marking brick isolation RS 485 output; 1 isolated 4-20mA or 0-20mA output (active or passive options available); Optional HART protocol; Dual-channel partition ○ CT output (0CT1 pulse width programmable between 6 and 1000ms, default 200ms); It features a 1-channel bidirectional serial peripheral universal interface, which can directly connect multiple external devices such as 4-20mA analog output boards, frequency signal output boards, thermal printers, and data loggers in series.
5. Optional input: Three 4-20mA analog input circuits;
6. Display :2×10 Chinese backlit display (bilingual options in Chinese and English are available);
7. Operation: 16-key or 4-key windowed operation;
8. Other functions: Automatically remember the positive and negative net cumulative flow of the previous 512 days, the previous 128 months, and the previous 10 years. Automatically remember the on-off and power-off times and flow of the previous 30 times, and can achieve automatic or manual replenishment. It can also be read through the MODBUS protocol. Flow sensor: external digital type, insertion type and pipe section type